Transformer Rectifier (TR)
The transformer rectifier (TR) may be produced with different controls upon request (or according to cathodic
protection design). Air cooled TRs are designed for applications where lower current units are required, generally
up to 50 amperes. They are suitable for environments in ambient temperatures up to 55°C whether indoors or
outside. The units are generally smaller and of lighter weight than oil cooled transformer rectifiers and are particularly
suited to non-hazardous areas where the size and weight of oil cooled TR would make installation prohibitive. Oil
cooled transformer rectifiers are ideally suited to heavy duty applications in arduous environments with ambient
temperatures up to 55°C and are available with current ratings of up to 400 amperes.
Specifications of Transformer Rectifier: Air-cooled transformer rectifier specifications
Item Parameter | Single Phase | Three Phase | PWM Switch | Mounted Type | Portable type |
Frequency | 50Hz~60Hz | 50Hz~60Hz | 50Hz~60Hz | 50Hz~60Hz | 50Hz~60Hz |
AC Input Voltage | 220V | 380V | 220V | 220V | 220V |
DC Output Voltage | DC 0~50V | DC 0~100V | DC 0~50V | DC 0~50V | DC 0~50V |
DC Output Current | 0~50A | 0~300A | 0~80A | 0~40A | 0~20A |
Current limiting | 0~30A | 0~200A | 0~60A | 0~30A | 0~15A |
Set potential | 0~±3V | 0~±3V | 0~±3V | 0~±3V | 0~±3V |
Constant potential precision | ≤5mV | ≤5mV | ≤5mV | ≤5mV | ≤5mV |
Constant current precision | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% |
Input Impedance | ﹥5MΩ | ﹥5MΩ | ﹥5MΩ | ﹥5MΩ | ﹥5MΩ |
Ripple | ≤3% | ≤3% | ≤3% | ≤3% | ≤3% |
Surge Arrester | Configured | Configured | Configured | Configured | Configured |
Working Style | Continuous | Continuous | Continuous | Continuous | Continuous |
IP Protection (Optional) | IP 54~IP 66 | IP 54~IP 66 | IP 54~IP 66 | IP 54~IP 66 | IP 54~IP 66 |
AC Noise Immunity | ≥24V | ≥24V | ≥24V | ≥24V | ≥24V |
Remote Data Transmission & Remote control | Optional | Optional | Optional | Optional | Optional |
Circuit Structure | Modularization | Modularization | Modularization | Modularization | Modularization |
Oil-cooled transformer rectifier specifications
Item Parameter | Single Phase | Three Phase | PWM Switch | Mounted Type | Portable type |
Frequency | 50Hz~60Hz | 50Hz~60Hz | 50Hz~60Hz | 50Hz~60Hz | 50Hz~60Hz |
AC Input Voltage | 220V | 380V | 220V | 220V | 220V |
DC Output Voltage | DC 0~50V | DC 0~100V | DC 0~50V | DC 0~50V | DC 0~50V |
DC Output Current | 0~50A | 0~300A | 0~80A | 0~40A | 0~20A |
Current limiting | 0~30A | 0~200A | 0~60A | 0~30A | 0~15A |
Set potential | 0~±3V | 0~±3V | 0~±3V | 0~±3V | 0~±3V |
Constant potential precision | ≤5mV | ≤5mV | ≤5mV | ≤5mV | ≤5mV |
Constant current precision | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% |
Input Impedance | ﹥5MΩ | ﹥5MΩ | ﹥5MΩ | ﹥5MΩ | ﹥5MΩ |
Ripple | ≤3% | ≤3% | ≤3% | ≤3% | ≤3% |
Surge Arrester | Configured | Configured | Configured | Configured | Configured |
Working Style | Continuous | Continuous | Continuous | Continuous | Continuous |
IP Protection (Optional) | IP 54~IP 66 | IP 54~IP 66 | IP 54~IP 66 | IP 54~IP 66 | IP 54~IP 66 |
AC Noise Immunity | ≥24V | ≥24V | ≥24V | ≥24V | ≥24V |
Remote Data Transmission & Remote control | Optional | Optional | Optional | Optional | Optional |
Circuit Structure | Modularization | Modularization | Modularization | Modularization | Modularization |
*The power rating of the above transformer rectifier was optional from 500w to 30kw